My Cart

WECO UF844-IXPT Polymeric Ultrafiltration Backwashing Water Filtration System

SKU
UF844-IXPT
Be the first to review this product
Price: $5,862.43
Free Shipping
Freight Shipment
Parts In stock
- +
  • Utilizes Patented Outside/In Enpress Polymeric Membrane Filtration Module that is NSF 61, EPA, ACS and CDHS certified. BioVir certified and tested module for log reduction of Bacteria and Virus.
  • Four bundles of 0.02 micron filtration membranes in each vessel in a twin alternating configuration.
  • Reach out to us for silica reduction solutions. Pilot testing required. Our system effectively removes suspended silica particles larger than 0.02 microns. Smaller silica in solution may pass through the membrane.
  • High performance flow rates, up to 10 gpm.
  • Standard 1" MNPT ports with 1/2" MNPT drain.
  • Standard bottom drain flush valve removes any filter particles that have accumulated at the bottom of the UF.
  • Low waste water discharge used when cleaning. Treated water backwash increases membrane life.
  • Designed for cyst reduction, turbidity, and fine sediment filtration applications.
  • Influent water must meet these requirements. Please contact WECO for pre-treating water. Pilot testing with UF-PLT-STK advised.
    Influent Parameters: Pre-Filtration <5 Microns, 1 PPM Chlorine,0.3 PPM Iron, 0.05 PPM Manganese, Plus Others See Pre-treatment Section Below.
99 Percent Contaminant Removal

10 GPM
High Flow
Rate

Engineered for demanding applications, maintaining a stable and continuous flow of treated water.

WECO Crystal Clear Water

0.02
Micron
Ultrafiltration

Four ultra-dense membrane bundles in a twin alternating setup ensure absolute water purification.

Pre-Assembled and DIY Friendly

Suspended
Silica
Control

Effectively blocks silica particles larger than 0.02 microns. Custom pilot testing is available.

Pre-Assembled and DIY Friendly

Pre-Treatment
Limits

A built-in valve allows for quick, effortless purging of accumulated bottom sediment.

Pre-Assembled and DIY Friendly

Standardized
Connections

Equipped with 1" MNPT main ports and a 1/2" MNPT drain for seamless plumbing integration.

Pre-Assembled and DIY Friendly

Bottom
Flush Drain

A built-in valve allows for quick, effortless purging of accumulated bottom sediment.

Standard softening systems leave microscopic threats behind. The WECO UF844-IXPT is the final polishing stage that blocks 99.99% of microorganisms and impurities down to 0.02 microns

99 Percent Contaminant Removal

Certified
Enpress
Membrane

Patented Outside/In technology. NSF 61 and BioVir certified for maximum bacteria and virus reduction.

WECO Crystal Clear Water

Efficient
Regeneration

Engineered for demanding applications, maintaining a stable and continuous flow of treated water.

Pre-Assembled and DIY Friendly

Cyst & Turbidity
Barrier

Equipped with 1" MNPT main ports and a 1/2" MNPT drain for seamless plumbing integration.

Hydron Membrane
Hydron Membrane
Hydron Membrane
Hydron Membrane
Hydron Membrane
Hydron Membrane
WECO Crystal Clear Water

Continuous supply of purified water 24/7

Pre-Assembled and DIY Friendly

Consistent high performance, even under peak water demand

99 Percent Contaminant Removal

Automatic membrane self-cleaning, no user required

99 Percent Contaminant Removal

Extended membrane lifespan

99 Percent Contaminant Removal

Minimal water loss during backwashing cycles

99 Percent Contaminant Removal

No downtime during maintenance and cleaning operations

Two independent ultrafiltration modules operate alternately to provide continuous water purification. While one membrane filters water, the other is automatically cleaned.

Hydron Membrane

Operational Parameters

Design Parameters

  • Operation Pressure: 10 to 100 psi
  • Operating Temperature: 35 to 100°F
  • Continuous Flow Rate: 10 GPM
  • The system provides a treated flow of up to 10 GPM at 25°C and 60 psi.

Pre-treatment

  • Iron and Manganese: Reduce iron to <0.3 ppm and manganese to <0.05 ppm
  • Sediment: 5 microns or less
  • Silt Density Index: Less than 6.0
  • pH: 3 to 11
  • Chlorine: 1.0 ppm maximum for continuous flow (up to 2000 ppm for cleaning only)

Backwash Requirements

  • Automatic backflush performed every midnight for 5 minutes @ 7.2 GPM
  • Drain flush once a week for 2 minutes @ 5 GPM (simply open bottom drain valve)

Contaminant Reduction

  • Treats colloids, bacteria, cysts, viruses, turbidity, tannins, and other particles down to 0.02 microns in size.

Specification

Hydron Membrane

Professional Plumbing Support Recommended

Improper installation may cause leaks and water damage. Check all fittings carefully. WECO is not liable for damage caused by leaks.

Filtering Well Water?

Prior to placing an order, provide us with a comprehensive water quality analysis of your private well for a customized solution.

Alternatively, choose our basic well water test kit, and we will conduct the test on your behalf

More Information
UPC 749460855620
You're reviewing:
You're reviewing: WECO UF844-IXPT Polymeric Ultrafiltration Backwashing Water Filtration System

Browse File to Upload

Your Question : WECO UF844-IXPT Polymeric Ultrafiltration Backwashing Water Filtration System

Browse File to Upload

No question found!